Dryad Silvanet Documentation
Get StartedExplore SilvanetPlan a SiteDeploy SilvanetFAQ
  • Dryad Silvanet Documentation
  • Tutorials
    • Get started tutorial (Gen 2)
    • Get started tutorial (Gen 3)
    • Planning tool tutorial
  • Silvanet Suite
    • Explore Silvanet
    • Silvanet Suite (Gen 2)
      • Silvanet Wildfire Sensor (Gen 2)
      • Silvanet Mesh Gateway (Gen 2)
      • Silvanet Border Gateway (Gen 2)
    • Silvanet Suite (Gen 3)
      • Silvanet Wildfire Sensor (Gen 3)
      • Silvanet Mesh Gateway (Gen 3)
      • Silvanet Border Gateway (Gen 3)
    • Silvanet Cloud Platform
    • Silvanet Mesh Network
    • Site Management App
      • User access
      • Dashboard
      • Sites view
      • Site details
        • Device overview
        • Wildfire Sensor data
        • Device info tabs
      • Map view
      • Alert center
      • User Management view
      • User preferences
    • Deployment App
    • Fire detection
  • Site Planning
    • Plan Sites
    • Planning guidelines
      • Deployments stages
      • Scout deployment locations
      • Gateway ratios
      • Gateway ranges
      • Sensor ratios
      • Sensor range
      • Sensor density
    • Coverage planning
      • Planning tool
      • Import KML, KMZ and Shapefiles
      • High density paths
      • Low density areas
      • Connectivity zones
      • Add or move Sensors
      • Export plan
    • Packet editor
  • Silvanet Deployment
    • Deploy Silvanet
    • Deployment guidelines
      • Deployment preparation
      • Border Gateway guidelines
      • Border Gateway scenarios
      • Mesh Gateway guidelines
      • Wildfire Sensor guidelines
    • Deploy Border Gateways (Gen 2/3)
      • Register Border Gateway
      • Mount Border Gateway (Gen 2)
      • Mount Border Gateway (Gen 3)
      • Border Gateway Connectivity Test
    • Deploy Mesh Gateways (Gen 2/3)
      • Register Mesh Gateway
      • Mount Mesh Gateway (Gen 2)
      • Mount Mesh Gateway (Gen 3)
      • Mesh Gateway Connectivity Test
    • Deploy Wildfire Sensors
      • Register Wildfire Sensors
      • Mount Wildfire Sensors
      • Sensor Calibration
      • Sensor normalization
    • Relocate a Silvanet Sensor or Gateway
  • Silvanet API
    • Silvanet API - MQTT Sensor Data Integration
    • Silvanet API - Webhook Integration
  • Silvanet Test Fires
    • Overview
    • Test fire preparation
    • Run test fires
    • Modify fire setups
  • Resources
    • Contact Technical Support
    • Release Notes
    • FAQs
      • General Questions
      • Border Gateway FAQs
      • Mesh Gateway FAQs
      • Wildfire Sensor FAQs
      • Site Management FAQs
      • User Management FAQs
    • Glossary of Terms
    • Status icons
    • Device troubleshooting
    • Firmware updates (FUOTA)
    • Declaration of Conformity (EU)
  • Chandler Burning Index (CBI)
Powered by GitBook

Docs Version

  • Version 4.6.4

Sales Enquiry

  • Contact Dryad Sales

Dryad

  • Dryad.net

© 2025, Dryad Networks GmbH, Eisenbahnstr. 37, 16225 Eberswalde, Germany

On this page
  • Overview
  • Key Features
  • New features
  • Deployment features
  • Environmental monitoring
  • Regulatory compliance
  • LoRa Radio
  • Delivered components
  • Dimensions and weight
  • Environmental detection
  • Energy harvesting (solar panel)
  • Supercapacitor Energy Storage
  • Energy consumption
  • Idle/active modes
  • Sensor calibration
  • Firmware update

Was this helpful?

Export as PDF
  1. Silvanet Suite
  2. Silvanet Suite (Gen 3)

Silvanet Wildfire Sensor (Gen 3)

Silvanet Wildfire Sensors provide ultra-early detection of fires by monitoring the environment to detect gases associated with smoldering fires and alert users.

PreviousSilvanet Suite (Gen 3)NextSilvanet Mesh Gateway (Gen 3)

Last updated 1 month ago

Was this helpful?

Dryad's 3rd Generation Silvanet Wildfire Sensor is designed to detect forest fires within minutes, often during their early smoldering phase. This reduces the risk of the fire spreading out of control and allows firefighters to extinguish smoldering fires before they spread.

The Wildfire Sensors now have an updated, endurable casing and incorporates NFC for offline device registration and local debugging.

The Sensors are mounted directly on trees using tree nails or securely attached to poles or fenceposts using garden wire.

See Also

Overview

The Silvanet Wildfire Sensor monitors the forest’s microclimate, measuring temperature, humidity, and air pressure within a radius of 80 m to 100 m (260 ft to 320 ft). It combines ultra-low-power air quality sensing with a precise gas sensing mode.

As the end-device, it uses LoRaWAN to communicate with the Silvanet Mesh Network and can operate maintenance-free for 10-15 years. Energy is stored in supercapacitors rather than batteries to prevent the Sensors from being a source of fires themselves.

Range of Sensors

Silvanet Wildfire Sensors can detect fires within a 100 m range.

Ratio of Sensor to Mesh Gateway

Up to 100 Silvanet Wildfire Sensors can be supported by a single Silvanet Mesh Gateway.

Key Features

Gen 3 Silvanet Wildfire Sensors have an updated design for better gas sensing and allows device registration using NFC.

New features

  • Integrated NFC: Integrates NFC for registering and connectivity testing (using the Silvanet Deployment app) and for offline local debugging.

  • New gas sensor: Updated gas sensor for improved fire detection capabilities.

Deployment features

  • Detection radius: Deployed every 100 m (typical) for a fire detection range of 100 m radius for 60 minute detection of a 2 m x 3 m fire.

  • Maintenance free:

    Runs maintenance free for 10 to 15 years without the need of batteries.

  • Weatherproof casing design:

    Endurable casing design (weather/UV proof) with IP67 Ingress protection. Integrated loop for quickly mounting on trees or wooden poles with a single tree nail and spacer (at minimum 3 m above forest floor).

  • Solar powered

    Power is supplied by a built-in 6 x 6 cm solar panel. As a precaution against the device itself starting a fire, it stores its energy in supercapacitors rather than batteries. This avoids the use of lithium and other toxic materials.

  • LoRaWAN connectivity:

    LoRa-integrated radio sends and receive messages to the robust LoRaWAN Silvanet Mesh Network (Mesh Gateways and Border Gateways).

  • Firmware update: Remotely update firmware using FUOTA (Firmware Update Over-the-Air).

Environmental monitoring

  • Bosch gas sensor combines ultra-low-power Air Quality sensing with a precise gas sensing mode. It is a low-energy hydrogen sensor that can detect the presence of a smoldering fire over distances of up to 115 m.

  • Detects the presence of Volatile Organic Compounds (VoCs) and Volatile Sulfur Compounds (VSC) and detects these compounds at <20 ppm.

  • The gas sensor detects CO (Carbon Monoxide), H2, (Hydrogen) and VOC (Volatile Organic Compounds) at the ppm level with built-in artificial intelligence (AI) to reliably detect a fire and avoid false positives.

  • Monitors the microclimate of the forest by reading temperature, humidity and air pressure.

Regulatory compliance

  • USA (FCC, PTCRB)

  • Canada (IC)

  • Europe (CE RED)

  • CB Scheme

LoRa Radio

  • ISM Bands: NA902-928, AU915, EU868, AS923

  • Tx Power: 14 dBm

Delivered components

  • 10 Wildfire Sensors

  • 10 tree nails

  • 10 spacers

  • Garden wire

Dimensions and weight

The dimensions of the Silvanet Wildfire Sensor are (LxWxH) 19 cm x 9.2 cm x 1.34 cm. It weighs 136 grams.

Ingres protection

Ingress protection of the housing is IP67. This means the housing is completely protected against dust and is watertight.

Environmental detection

The Silvanet Wildfire Sensor uses a Bosch gas sensor to monitor the microclimate of the forest. It is a low-energy hydrogen sensor that detects the presence of a smoldering fire over distances of up to 115 m.

The gas sensor detects the presence of CO (Carbon Monoxide), H2, (Hydrogen), VOCs (Volatile Organic Compounds) and VSCs (Volatile Sulfur Compounds). It detects VOC and VSC compounds at <20 ppm. It monitors the microclimate of the forest by providing measurements under the following conditions:

  • Air pressure: 300 hPa to 1100 hPa

  • Humidity: 0% to 100% condensing

  • Temperature: -40°C to +85°C

Energy harvesting (solar panel)

The Silvanet Wildfire Sensor includes a 60 mm x 60 mm solar cell on its front housing.

Each day the solar panel harvests 7Ws in the constrained conditions of a forest.

The solar panel provides sufficient energy supply to support continuous operation over a 24hr period while still having enough reserve power to support the powering of the gas sensor and to send a burst of messages when a smoldering fire is detected.

It continuously generates energy during the daytime and recharges the device with sufficient power for after sunset. It then begins to discharge until sunrise. After sunrise, it begins to recharge to 100% within about an hour.

Charging superconductors within forests

Sufficient ambient light is available in forests to provide sufficient light for the solar panel. Forests are never entirely dark during the day, even with a thick forest canopy.

Supercapacitor Energy Storage

The Silvanet Wildfire Sensor uses a set of supercapacitors to store energy for use by the radio, gas sensor and other components. It stores the energy for day-to-day tasks and has a reasonable amount of reserve power to operate the gas sensor and radio module in case a potential fire is detected.

As supercapacitors have an expected lifespan of 10 years or more, the sensors are essentially maintenance free. This allows for an expected lifespan of the sensor between 10 and 15 years.

Supercapacitors have a high capacity but a small maximum voltage of 2.7 V so a series of capacitors are loaded to 4 V. Capacitors are fully charged to 5.2 V.

Why use supercapacitors?

Power supply is stored in supercapacitors rather than rechargeable batteries as they can potentially ignite. Consequently, using batteries would defeat the purpose of a wildfire detection system.

Energy consumption

Wildfire Sensor energy consumption

The Wildfire Sensor consumes 0.7 mW per day (63 Joule per day). This allows it to operate in a shaded location for ~6 hrs.

The two key components that consume energy are the gas sensor and the LoRa radio:

  • The gas sensor consumes ~3.9 mA in standard gas scan mode.

Idle/active modes

Normally, the Silvanet Wildfire Sensor is in idle mode. Every 60 seconds it enters active mode to read the air quality. Then, every 2 hours it reads the environment after which it sends a single packet to the Silvanet Cloud Platform via Mesh Gateways and Border Gateways.

Steps
Mode
Duration

Normal State

Idle mode

60 seconds

Every 60 seconds

Active mode - Check Air Quality

1 second

Every 2 hours

Active mode - check Air Quality and send data packet.

1 second

These data packets contain normal (non-fire detection) environmental data which includes temperature, pressure and humidity internal values.

These values are then displayed in the Site Details section of the Site Management app.

See Also

Sensor calibration

After deployment, the Wildfire Sensor requires 14 days to calibrate. Until then it can generate false alarms.

See Also

Firmware update

The Silvanet Wildfire Sensor supports FUOTA (Firmware Update Over The Air).

Using FUOTA, the Wildfire Sensor can successfully and securely receive firmware updates even if its power supply is interrupted.

See Also


Deploying Wildfire Sensors

For information about deploying Silvanet Wildfire Sensors, see .

For more information, see .

For more information, see .

The Silvanet Wildfire Sensor has very low energy consumption which is provided by its built-in .

LoRa radio - see .

For more information, see .

For more information, see .

For more information, see .

For more information about deploying Wildfire Sensors see and .

Deploy Wildfire Sensors
Wildfire Sensor data
Sensor Calibration
Firmware updates (FUOTA)
Planning guidelines
Deploy Wildfire Sensors
solar panel
Idle/active modes
Sensor range
Sensor ratios
Silvanet Wildfire Sensor
Silvanet Wildfire Sensor dimensions