Dryad Silvanet Documentation
Get StartedExplore SilvanetPlan a SiteDeploy SilvanetFAQ
  • Dryad Silvanet Documentation
  • Tutorials
    • Get started tutorial (Gen 2)
    • Get started tutorial (Gen 3)
    • Planning tool tutorial
  • Silvanet Suite
    • Explore Silvanet
    • Silvanet Suite (Gen 2)
      • Silvanet Wildfire Sensor (Gen 2)
      • Silvanet Mesh Gateway (Gen 2)
      • Silvanet Border Gateway (Gen 2)
    • Silvanet Suite (Gen 3)
      • Silvanet Wildfire Sensor (Gen 3)
      • Silvanet Mesh Gateway (Gen 3)
      • Silvanet Border Gateway (Gen 3)
    • Silvanet Cloud Platform
    • Silvanet Mesh Network
    • Site Management App
      • User access
      • Dashboard
      • Sites view
      • Site details
        • Device overview
        • Wildfire Sensor data
        • Device info tabs
      • Map view
      • Alert center
      • User Management view
      • User preferences
    • Deployment App
    • Fire detection
  • Site Planning
    • Plan Sites
    • Planning guidelines
      • Deployments stages
      • Scout deployment locations
      • Gateway ratios
      • Gateway ranges
      • Sensor ratios
      • Sensor range
      • Sensor density
    • Coverage planning
      • Planning tool
      • Import KML, KMZ and Shapefiles
      • High density paths
      • Low density areas
      • Connectivity zones
      • Add or move Sensors
      • Export plan
    • Packet editor
  • Silvanet Deployment
    • Deploy Silvanet
    • Deployment guidelines
      • Deployment preparation
      • Border Gateway guidelines
      • Border Gateway scenarios
      • Mesh Gateway guidelines
      • Wildfire Sensor guidelines
    • Deploy Border Gateways (Gen 2/3)
      • Register Border Gateway
      • Mount Border Gateway (Gen 2)
      • Mount Border Gateway (Gen 3)
      • Border Gateway Connectivity Test
    • Deploy Mesh Gateways (Gen 2/3)
      • Register Mesh Gateway
      • Mount Mesh Gateway (Gen 2)
      • Mount Mesh Gateway (Gen 3)
      • Mesh Gateway Connectivity Test
    • Deploy Wildfire Sensors
      • Register Wildfire Sensors
      • Mount Wildfire Sensors
      • Sensor Calibration
      • Sensor normalization
    • Relocate a Silvanet Sensor or Gateway
  • Silvanet API
    • Silvanet API - MQTT Sensor Data Integration
    • Silvanet API - Webhook Integration
  • Silvanet Test Fires
    • Overview
    • Test fire preparation
    • Run test fires
    • Modify fire setups
  • Resources
    • Contact Technical Support
    • Release Notes
    • FAQs
      • General Questions
      • Border Gateway FAQs
      • Mesh Gateway FAQs
      • Wildfire Sensor FAQs
      • Site Management FAQs
      • User Management FAQs
    • Glossary of Terms
    • Status icons
    • Device troubleshooting
    • Firmware updates (FUOTA)
    • Declaration of Conformity (EU)
  • Chandler Burning Index (CBI)
Powered by GitBook

Docs Version

  • Version 4.6.4

Sales Enquiry

  • Contact Dryad Sales

Dryad

  • Dryad.net

© 2025, Dryad Networks GmbH, Eisenbahnstr. 37, 16225 Eberswalde, Germany

On this page
  • CE Radiation Exposure Statement
  • CE Operating Bands and Maximum Output Power
  • LoRa
  • 2G
  • LTE Cat-M1 (eMTC)
  • LTE Cat-NB1 (NB-IoT)
  • USA Compliance
  • FCC Statement
  • FCC Radiation Exposure Statement
  • FCC Caution
  • Canada Compliance
  • ISED Statement
  • ISED Radiation Exposure Statement
  • CB safety statement

Was this helpful?

Export as PDF
  1. Resources

Declaration of Conformity (EU)

CE Radiation Exposure Statement

This equipment should be installed and operated with a minimum distance of 24 cm between the radiator and your body. EU Compliance

CE Operating Bands and Maximum Output Power

Equipment
Model
PoE Layout
Cellular (WWAN)
Satellite

Silvanet Border Gateway

SBG-2

With

With

With

Silvanet Mesh Gateway

SMG-2

Without

Without

Without

LoRa

Bands
Gain (dBi)
Power (dBm)
EIRP (dBm)

M

5

11.02

16.02

N

5

10.65

15.65

P

5

19.30

24.30

2G

Bands
Gain (dBi)
Power (dBm)
EIRP (dBm)

900

-0.03

35

34.97

1800

2.45

35

37.45

LTE Cat-M1 (eMTC)

Bands
Gain (dBi)
Power (dBm)
EIRP (dBm)

B1

1.38

25.70

27.08

B3

2.45

25.70

28.15

B8

-0.03

25.70

25.67

B20

-0.4

25.70

25.30

B28

-0.25

25.70

25.45

LTE Cat-NB1 (NB-IoT)

Bands
Gain (dBi)
Power (dBm)
EIRP (dBm)

B1

1.38

25.70

27.08

B3

2.45

25.70

28.15

B8

-0.03

25.70

25.67

B20

-0.4

25.70

25.30

B28

-0.25

25.70

25.45

Referred to Article 10(9), CE simplified EU declaration of conformity.

USA Compliance

FCC Statement

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:

(1) This device may not cause harmful interference, and

(2) this device must accept any interference received, including interference that may cause undesired operation.

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.

  • Increase the separation between the equipment and receiver.

  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.

  • Consult the dealer or an experienced radio/TV technician for help.

This device and its antenna(s) must not be co-located or operating in conjunction with any other antenna or transmitter.

FCC Radiation Exposure Statement

This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 23cm between the radiator and your body.

FCC Caution

Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment.

Canada Compliance

This Class B digital apparatus complies with Canadian ICES-003.

Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada.

ISED Statement

This device contains licence-exempt transmitter(s)/receiver(s) that comply with Innovation, Science and Economic Development Canada’s licence-exempt RSS(s). Operation is subject to the following two conditions:

  1. This device may not cause interference.

  2. This device must accept any interference, including interference that may cause undesired operation of the device.

The transmitter module may not be co-located with any other transmitter or antenna.

L’émetteur/récepteur exempt de licence contenu dans le présent appareil est conforme aux CNR d’Innovation, Sciences et Développement économique Canada applicables aux appareils radio exempts de licence. L’exploitation est autorisée aux deux conditions suivantes :

  1. L’appareil ne doit pas produire de brouillage;

  2. L’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d’en compromettre le fonctionnement.

Le module émetteur peut ne pas être coïmplanté avec un autre émetteur ou antenne.

ISED Radiation Exposure Statement

This equipment complies with ISED RSS-102 radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 34cm between the radiator and your body.

Cet équipement est conforme aux limites d’exposition aux rayonnements IC établies pour un environnement non contrôlé. Cet équipement doit être installé et utilisé avec un minimum de 34cm de distance entre la source de rayonnement et votre corps.

CB safety statement

This product is intended to be supplied by a Listed PoE Adapter marked “L.P.S.” (or Limited Power Source or PS2) rated 36-57V DC, 0.3A minimum, maximum altitude during operation below 5000m. For more information regarding approved power sources, please contact Dryad Networks GmbH.

PreviousFirmware updates (FUOTA)NextChandler Burning Index (CBI)

Last updated 6 months ago

Was this helpful?

Hereby, Dryad Networks GmbH declares that the radio equipment type 1. Silvanet Border Gateway, SBG-2; 2. Silvanet Mesh Gateway, SMG-2 are in compliance with Directive 2014/53/EU. The full text of the EU declaration of conformity is available at the following address:

FCC Company contact details Name: Dryad Networks GmbH Contact: